Corrosion Studies of Steel Alloy Materials - Equilibar control valves

Corrosion Studies of Steel Alloy Materials

Equilibar back pressure regulators used in flow control or pressure control for steel alloy studies

Corrosion studies for understanding performance of steel alloy materials used in oil and gas fields and in deep water flexible pipes have been performed extensively. With the development of carbon capture and storage (CCS) technology using supercritical carbon dioxide (SCO2), the corrosion effect of impurities in liquid CO2 is also of interest. Additionally, studies to understand material performance in supercritical water applications are important as supercritical H2O becomes more popular.

Flow control for corrosion studies of impurities in CO2

Carbon steel corrodes in presence of carbon dioxide (CO2) and supercritical CO2. When hydrogen sulfide (H2S) or other impurities such as NO2 and SO2 are also present, corrosion rate may increase, and cracking or pitting failures may be a concern. Researchers want to understand the effect of precise impurity levels on a variety alloys to find the best solution for energy sector clients. Steel corrosion studies are performed under carefully controlled temperature and pressure conditions.

Equilibar flow control valves in conjunction with Coriolis mass flow meters provide precision flow control of CO2 mixtures for corrosion studies

An example setup is shown in the schematic above. A series of pressurized reservoirs are filled with CO2 mixed with various types of impurities for the study. Fluids are delivered at specific rates to an environmental chamber where the corrosion studies take place. An Equilibar® flow control valve combined with a mass flow meter work together to provide the precise ratio of impurities needed for the corrosion study.

Advantages of using an Equilibar valve for this application are its precision control, fast response to changing setpoint needs, and its capacity to operate across a wide range of flow rates in one single valve. Equilibar valves can also be manufactured with chemical resistant materials which is beneficial in this case.

Want to learn more? Contact an Equilibar application engineer for more information.

Equilibar research series high pressure BPR

An Equilibar low flow valve with an electro-pneumatic pilot regulator can be used for flow control in corrosion studies

 

Contact Us
Download Flow Control Brochure

Pressure control for corrosion studies of supercritical fluids

Supercritical CO2 is used for carbon sequestration, so it is important to understand corrosion properties of piping and transport vessels carrying SCO2. Additionally, turbomachinery design for supercritical CO2 power cycles benefits from understanding corrosion properties of metal alloys.

Fluids reach supercritical state at high temperatures and pressures. For effective corrosion studies, reactors must maintain consistent pressure control over a period of exposure time. Equilibar has back pressure regulators capable of controlling the high pressures and temperatures required in supercritical applications. Equilibar also has regulators designed specifically for supercritical use with features that maintain high precision control while reducing the Joule-Thomson effect of supercritical process fluids passing through the outlet orifices.

schematic of supercritical corrosion testing

An Equilibar back pressure regulator controls supercritical test chamber for corrosion testing

Contact an Equilibar application engineer to discuss your application today.

Work Categories
Equilibar News
PUK magazine cover with stainless steel device

Journal article focuses on oligonucleotide production using pressure control with built in dampener

Oligonucleotide drugs are made up of short sections of genetic sequences and are used to target disorders in the genetic code. The first drug of this type was used in 1998 during the AIDS epidemic.  Since then, the field has accelerated rapidly and today many oligonucleotide drugs are in clinical trials, promising improvements in treatment Read More