Equilibar EVR Vacuum Regulators are especially well suited for the complex demands of glovebox pressure control and are capable of controlling vacuum pressure in a glovebox down to the range of 1 inH2O (2 mbar). One of Equilibar’s glovebox applications was featured in the November 2017 Flow Control Magazine.

In many glovebox situations, it is desirable to control pressure differential in order to improve dexterity of the operator’s gloves. At the same time, however, it is important to provide for stronger vacuum supply in the event of a compromised glove or opened hatch. A vacuum regulator can restrict the flow to the vacuum fan during normal operations and provide a surge of flow when needed to maintain pressure.

Vacuum-Glovebox-Control

Remote Sense for control across filter

In some critical applications, such as hazardous material handling, a HEPA filter is required downstream of the glove box and before the vacuum supply header or fan. The presence of this pressure drop can be problematic when controlling chamber pressure in the millibar range, and requires the use of a Remote Sense control capability.

The Equilibar EVR comes with a vacuum pilot controller which allows the user to set the glove box set-point. This pilot also monitors the pressure directly in the glove box and automatically adjusts the pressure sent to the EVR dome until the process is at the desired pressure.

Inert Gas Glove Box

Inert gas is required for certain demanding glove box applications. In these situations, the expense of nitrogen or argon necessitates that gas flow is minimized. If a vacuum is also required on the enclosure, the vacuum regulator must be capable of controlling the exhaust flow from a very low value (normal operations) to a high value (during glove failure or hatch open condition).

Vacuum-Glovebox-Control-Inert-Gas

Control pressure ranges for the Equilibar EVR vacuum regulator ranges from approximately 1 inH2O (2 mbar) up through the full vacuum range (30 inHG). For glove box applications, the common range is around 1 to 4 inH2O (2 to 8 mbar).

glovebox pressure control

Flow Control Magazine Features the Equilibar in a glovebox application

 

The HV Series vacuum valve is suitable for high flow glove box applications. Sizes for the HV Series are 2", 4", and 6". Available in T304 and T316L stainless steel.

The HV Series vacuum valve is suitable for high flow glove box applications. Sizes for the HV Series are 2″, 4″, and 6″. Available in T304 and T316L stainless steel.

SS316-vacuum-valve

The BD Series Vacuum Valves are available in 1.5″, 2″, 3″, and 4″ (pipe or flange). Materials are SS316L, Aluminum, or PVC.

 

 

 

 

 

 

 

 

Work Categories
Equilibar News
PUK magazine cover with stainless steel device

Journal article focuses on oligonucleotide production using pressure control with built in dampener

Oligonucleotide drugs are made up of short sections of genetic sequences and are used to target disorders in the genetic code. The first drug of this type was used in 1998 during the AIDS epidemic.  Since then, the field has accelerated rapidly and today many oligonucleotide drugs are in clinical trials, promising improvements in treatment Read More

Read More