High Pressure Electronic Controller


EPR-3000

Precise, convenient control up to 3000 psig / 207 bar(g)

The EPR-3000 is a significant advance in the precision and convenience of electronic pressure control above 1000 psig / 69 bar(g).
Using dual analog valve construction, the EPR-3000 avoids the waste of inert supply gas present with some competitive solutions. The analog valves also provide for high resolution in the range of 0.1%.

  • For inert gas
  • Dual analog valve construction
  • No gas supply wasted at steady state
  • Very high resolution with 0.25% accuracy
  • Digital or analog communications with keypad option
  • Not intended for hazardous/explosive environments

Convenient Communication & Connections

The EPR-3000 can be quickly commanded using the convenient keypad interface. For system automation, the device can be automated through either the 0 – 5 VDC analog interface or by use of a Serial (RS-458) connection. Power supply for the unit (12 – 30 VDC) can be provided through an included power brick, or provided through the DIN connector.

Download Brochure


The EPR-3000 control pressure precisely in the high pressure range of 0 - 3000 psig / 0 - 206 bar(g)

The EPR-3000 control pressure precisely in the high pressure range of 0 – 3000 psig / 0 – 206 bar(g). ( Details)

 

Applications

The EPR-3000 is designed for static to low- flow applications of inert gas such as nitrogen or air.
One common application is to provide a high pressure pilot signal for dome-loaded regulators requiring pressures above 1000 psig / 69 bar(g). In the schematic at right, the EPR-3000 is used to control the output pressure of a catalyst research reactor. Because both the EPR-3000 and the back pressure regulator have no significant hysteresis or dead-band, it is possible to precisely control reaction conditions even with highly varying process flow rates.

Catalyst Research Reactor with EPR

How it Works

Two valve pressure controllers include a “fill” and “vent” valve. Outlet pressure is sensed and controlled through a type of PID loop. While many industrial pressure controllers utilize binary fill and vent valves, or analog fill valves with binary vent valves, the EPR-3000 uses two analog valves for highly precise and resolute control throughout the entire range.

EPR Schematic for EPR-3000

 

 

Equilibar News
valve mag featuring Equilibar

Valve Magazine features overview of Equilibar® technology

The summer 2022 issue of Valve Magazine includes a comprehensive overview of the direct sealing diaphragm valve technology that is at the core of Equilibar’s patented devices.  Written by Equilibar founder Jeff Jennings, the article explains the background of this unique method of fluid control and describes how it is capable of providing robust back Read More