{"id":37819,"date":"2022-09-28T15:01:56","date_gmt":"2022-09-28T19:01:56","guid":{"rendered":"https:\/\/www.equilibar.com\/?page_id=37819"},"modified":"2024-09-13T08:57:25","modified_gmt":"2024-09-13T12:57:25","slug":"equilibar-flow-control-using-eqda","status":"publish","type":"page","link":"https:\/\/www.equilibar.com\/ja\/flow-control-valves\/equilibar-flow-control-using-eqda\/","title":{"rendered":"Equilibar Flow Control using an EQ-DA Smart Controller"},"content":{"rendered":"<p><div class=\"grid\"><div class=\"c-two-third \">Equilibar\u00ae valves can easily be set up for flow control applications using a flow meter and control logic as explained on our <a href=\"https:\/\/www.equilibar.com\/flow-control-valves\/\">flow control page.<\/a> <\/p> <p>To review the various methods of control systems for setting up an Equilibar flow control valve (FCV), please visit our &#8220; <a href=\"https:\/\/www.equilibar.com\/flow-control-valves\/getting-started-with-equilibar-flow-control-valves\/\">getting started with flow control<\/a> &#8221; page.<\/p> <p>On this page you will find specific information about using an EQ-DA smart controller and accompanying browser-based GUI to set up a flow control loop with an Equilibar FCV.<\/p> <p>Below is a schematic showing how the EQ-DA and Equilibar flow control system is set up in the demonstration video that follows. The EQ-DA communicates through a browser-based GUI installed in the laptop. It receives a flow signal from the flow meter and sends a pressure signal to the pilot port of the Equilibar FCV. For best performance, we recommend setting up the flow controller with guidance from an on-site controls engineer experienced in tuning feedback loops.<\/p> <p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-37821\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg\" alt=\"\" width=\"763\" height=\"366\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg 763w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif-300x144.jpg 300w\" sizes=\"auto, (max-width: 763px) 100vw, 763px\" \/><\/p> <h3>Control using an EQ-DA smart controller and its browser-based GUI:<\/h3> <p>This video demonstrates how to set up the EQ-DA and use its accompanying browser-based GUI to control flow in a control loop using an Alicat flow meter and an Equilibar flow control valve.<\/p> <p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/GxMGYgoUED8\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p> <p><span class=\"style-scope yt-formatted-string\" dir=\"auto\">You can find the products we used in this video, at these links<\/span><\/p> <p><span class=\"style-scope yt-formatted-string\" dir=\"auto\"> <a href=\"https:\/\/www.alicat.com\/product\/coriolis-mass-flow-meters-and-controllers\/\">Alicat CODA Coriolis<\/a> <\/span><span class=\"style-scope yt-formatted-string\" dir=\"auto\">flow meter <\/span><\/p> <p><span class=\"style-scope yt-formatted-string\" dir=\"auto\"> <a href=\"https:\/\/www.pressurecontrolsolutions.com\/wp-content\/uploads\/2024\/06\/EQ-DA-Datasheet-2406.pdf\">EQ-DA diaphragm actuator<\/a> <\/span><\/p> <a id=\"button-counter-1\" class=\"button medium type-simple\" href=\"\/contact\/\" >Contact Us for more information<\/a> <\/div><div class=\"c-one-third \"> <p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-37830\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-scaled.jpg\" alt=\"photo of Equilibar flow control using EQ-DA\" width=\"2560\" height=\"1920\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-scaled.jpg 2560w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-300x225.jpg 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-1024x768.jpg 1024w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-768x576.jpg 768w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-1536x1152.jpg 1536w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/EQ-DA-flow-control-setup-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/p> <a id=\"button-counter-2\" class=\"button medium type-simple\" href=\"\/contact\/\" >Speak to an Engineer<\/a> <\/div><\/div><\/p> ","protected":false},"excerpt":{"rendered":"","protected":false},"author":16,"featured_media":37821,"parent":20350,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-sidebar-left.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-37819","page","type-page","status-publish","has-post-thumbnail","hentry","btp_relation_tag-s-techarticle"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.3 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Equilibar Flow Control Using an EQ-DA<\/title>\n<meta name=\"description\" content=\"An Equilibar flow control valve can be set up using an EQ-DA smart pilot controller and its browser-based GUI\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Equilibar Flow Control using an EQ-DA Smart Controller\" \/>\n<meta property=\"og:description\" content=\"An Equilibar flow control valve can be set up using an EQ-DA smart pilot controller and its browser-based GUI\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/\" \/>\n<meta property=\"og:site_name\" content=\"Equilibar\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Equilibar\/114261858601579\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-13T12:57:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"763\" \/>\n\t<meta property=\"og:image:height\" content=\"366\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@equilibar\" \/>\n<meta name=\"twitter:label1\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Equilibar Flow Control Using an EQ-DA","description":"An Equilibar flow control valve can be set up using an EQ-DA smart pilot controller and its browser-based GUI","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/","og_locale":"ja_JP","og_type":"article","og_title":"Equilibar Flow Control using an EQ-DA Smart Controller","og_description":"An Equilibar flow control valve can be set up using an EQ-DA smart pilot controller and its browser-based GUI","og_url":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/","og_site_name":"Equilibar","article_publisher":"https:\/\/www.facebook.com\/pages\/Equilibar\/114261858601579","article_modified_time":"2024-09-13T12:57:25+00:00","og_image":[{"width":763,"height":366,"url":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@equilibar","twitter_misc":{"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/","url":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/","name":"Equilibar Flow Control Using an EQ-DA","isPartOf":{"@id":"https:\/\/www.equilibar.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/#primaryimage"},"image":{"@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/#primaryimage"},"thumbnailUrl":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg","datePublished":"2022-09-28T19:01:56+00:00","dateModified":"2024-09-13T12:57:25+00:00","description":"An Equilibar flow control valve can be set up using an EQ-DA smart pilot controller and its browser-based GUI","breadcrumb":{"@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/#primaryimage","url":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg","contentUrl":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2022\/09\/Flow-control-with-EQ-DA-gif.jpg","width":763,"height":366,"caption":"Equilibar flow control schematic with EQ-DA"},{"@type":"BreadcrumbList","@id":"https:\/\/www.equilibar.com\/flow-control-valves\/equilibar-flow-control-using-eqda\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Equilibar Flow Control Valves","item":"https:\/\/www.equilibar.com\/flow-control-valves\/"},{"@type":"ListItem","position":2,"name":"Equilibar Flow Control using an EQ-DA Smart Controller"}]},{"@type":"WebSite","@id":"https:\/\/www.equilibar.com\/#website","url":"https:\/\/www.equilibar.com\/","name":"Equilibar","description":"Precision Fluid Control","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.equilibar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"}]}},"_links":{"self":[{"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/pages\/37819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/comments?post=37819"}],"version-history":[{"count":0,"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/pages\/37819\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/pages\/20350"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/media\/37821"}],"wp:attachment":[{"href":"https:\/\/www.equilibar.com\/ja\/wp-json\/wp\/v2\/media?parent=37819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}