{"id":16927,"date":"2018-12-04T11:20:11","date_gmt":"2018-12-04T15:20:11","guid":{"rendered":"https:\/\/www.equilibar.com\/?page_id=16927"},"modified":"2023-12-19T14:21:49","modified_gmt":"2023-12-19T18:21:49","slug":"vacuum-pilot-regulators","status":"publish","type":"page","link":"https:\/\/www.equilibar.com\/es\/vacuum-regulators\/vacuum-pilot-regulators\/","title":{"rendered":"How to Control Pilot Vacuum Pressure on Equilibar Vacuum Regulators"},"content":{"rendered":"<p><div class=\"grid\"><div class=\"c-two-third \">The Equilibar\u00ae vacuum regulator (EVR) is dome-loaded by vacuum pressure on top of the diaphragm and controls the inlet vacuum pressure to closely equal this &#8220;pilot vacuum pressure&#8221;. The pilot vacuum pressure on the dome may be regulated using a manual or an electronic vacuum regulator and may be operated in open loop or closed loop control schemes. The vacuum pilot control choice depends on the application performance requirements.<\/p> <p><em><strong>Note:<\/strong><\/em> While Equilibar EVRs are compatible with extreme chemical conditions, our vacuum pilot regulators and fittings are not. The flow through the vacuum pilot is from atmospheric to the inlet of the vacuum supply pump, so no chemicals should enter the vacuum pilot during normal operation. There is always a small bleed through the vacuum pilot regulators. Please see the bottom of our <a href=\"https:\/\/www.equilibar.com\/equilibar-safety-information\/\">safety design page<\/a> for more information. If you are using extreme chemicals, please <a href=\"https:\/\/www.equilibar.com\/contact\/\">speak to an application engineer<\/a> for details.<\/p> <p>Learn more about <a title=\"How the Equilibar Vacuum Regulator Works\" href=\"\/vacuum-regulators\/about-vacuum-regulators\/how-equilibar-works\/\">how our\u00a0vacuum regulators work<\/a>.<\/p> <p>The table below shows the benefits of the various vacuum pilot control layouts. For information about how to install a vacuum pilot regulator, watch the video lower down on this page.<\/p> <p> <a href=\"https:\/\/www.equilibar.com\/contact\/\">Contact an Equilibar application engineer<\/a> with questions or for help determining the best design for your vacuum application.<\/p> <\/div><div class=\"c-one-third \"><br \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-19800\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif\" alt=\"\" width=\"300\" height=\"189\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-572x360.gif 572w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p> <p style=\"text-align: center;\"><a id=\"button-counter-1\" class=\"button medium type-simple\" href=\"\/contact\/\" >Request Information<\/a><\/div><\/div> <h2>Vacuum Pilot Control Options<\/h2> <div class=\"table-wrapper\"><table class=\"simple\"> <thead> <tr> <th><\/th> <th>Open Loop Control<\/th> <th>Closed Loop Control<\/th> <\/tr> <\/thead> <tbody> <tr> <td><strong>Option Benefits<\/strong><\/td> <td> <ul> <li>Simple and robust<\/li> <li>Lower cost<\/li> <li>Best where flow is relatively stable<\/li> <li>Regulator is near process<\/li> <\/ul> <\/td> <td> <ul> <li>Higher Accuracy<\/li> <li>Higher Capacity<\/li> <li>Better where flows are varying widely<\/li> <li>Remote Sensing Capability<\/li> <\/ul> <\/td> <\/tr> <tr> <td>\u00a0<strong>Manual Controller Approach<\/strong><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17276 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechanical.jpg\" alt=\"schematic: open loop mechanical pilot\" width=\"362\" height=\"246\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechanical.jpg 362w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechanical-300x204.jpg 300w\" sizes=\"auto, (max-width: 362px) 100vw, 362px\" \/><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17286 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-mechanical.jpg\" alt=\"schematic of Equilibar EVR with mechanical closed loop control\" width=\"340\" height=\"234\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-mechanical.jpg 340w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-mechanical-300x206.jpg 300w\" sizes=\"auto, (max-width: 340px) 100vw, 340px\" \/><\/td> <\/tr> <tr> <td><strong>Electronic Controller Approach<\/strong><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17295 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechalectronic.jpg\" alt=\"schematic: electronic open loop control of Equilibar EVR\" width=\"351\" height=\"229\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechalectronic.jpg 351w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/open-loop-mechalectronic-300x196.jpg 300w\" sizes=\"auto, (max-width: 351px) 100vw, 351px\" \/><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17304 size-medium\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-electronic-300x196.jpg\" alt=\"schematic of electronic closed loop control of Equilibar EVR\" width=\"300\" height=\"196\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-electronic-300x196.jpg 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/closed-loop-electronic.jpg 365w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td> <\/tr> <\/tbody> <\/table><\/div> <\/p> <p>Customers can use the standard vacuum pilot regulator, SVP1 and SVP2, or request an upgrade to the RSV remote sense pilot regulator or the QPV1 or EPR-30 electronic pilot regulator. The table below outlined the options and types of pilot regulators.<\/p>  <h2>\u200bVacuum Pilot Regulators<\/h2> <div class=\"table-wrapper\"><table class=\"simple\"> <thead> <tr> <th><\/th> <th>SVP1<\/th> <th>SVP2<\/th> <th>RSV<\/th> <th>QPV<\/th> <th>EPR 30Hg<\/th> <\/tr> <\/thead> <tbody> <tr> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17329 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/DIM-C.jpg\" alt=\"Drawing of EVR pilot dimensions\" width=\"219\" height=\"193\" \/><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-8185 size-medium\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1857-web-249x300.jpg\" alt=\"GSD3 vacuum regulator\" width=\"249\" height=\"300\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1857-web-249x300.jpg 249w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1857-web.jpg 663w\" sizes=\"auto, (max-width: 249px) 100vw, 249px\" \/><\/td> <td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-8196 size-medium\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-297x300.jpg\" alt=\"BD12 vacuum\" width=\"297\" height=\"300\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-297x300.jpg 297w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-768x777.jpg 768w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-50x50.jpg 50w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-100x100.jpg 100w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web-47x47.jpg 47w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2017\/07\/MG_1865-web.jpg 791w\" sizes=\"auto, (max-width: 297px) 100vw, 297px\" \/><\/td> <td> <a href=\"https:\/\/www.equilibar.com\/application\/remote-sense-for-improved-vacuum-control\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10010 size-medium\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-300x300.jpg\" alt=\"image of Equilibar GS vacuum regulator with EVR remote sense pilot\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-300x300.jpg 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-150x150.jpg 150w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-50x50.jpg 50w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-100x100.jpg 100w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web-47x47.jpg 47w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/04\/EVR-with160A-web.jpg 750w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <\/td> <td> <a href=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-39418 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy.jpg\" alt=\"photo of an Equilibar vacuum regulator with electronic pilot regulator for automation\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy.jpg 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy-150x150.jpg 150w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy-50x50.jpg 50w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy-100x100.jpg 100w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2023\/12\/EVR-GSD8-QPV-M-300by300-Copy-47x47.jpg 47w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <\/td> <td> <a href=\"https:\/\/www.equilibar.com\/product\/electronic-pressure-regulators\/epr-30hg-electronic-vacuum-control\/\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-6480 size-medium\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-300x300.png\" alt=\"EPR-30 electronic vacuum pressure regulator\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-300x300.png 300w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-150x150.png 150w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-50x50.png 50w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-100x100.png 100w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller-47x47.png 47w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2016\/06\/dual-valve-pressure-controller.png 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <\/td> <\/tr> <tr> <td><strong>Control Type<\/strong><\/td> <td>Open Loop Manual Control<\/td> <td>Open Loop Manual Control<\/td> <td>Closed Loop Manual Control<\/td> <td>Open or Closed Loop Electronic Control<\/td> <td>Open or Closed Loop Electronic Control<\/td> <\/tr> <tr> <td><strong>EVR Port Sizes<\/strong><\/td> <td>1\/4&#8243; &#8211; 1&#8243;<\/td> <td>1 1\/2&#8243; &#8211; 4&#8243;<\/td> <td>All Sizes<\/td> <td>All Sizes<\/td> <td>All Sizes<\/td> <\/tr> <tr> <td><strong>DIM C (see dwg above)*<\/strong><\/td> <td>3 1\/4&#8243;<\/td> <td>3 3\/4&#8243;<\/td> <td>5 1\/4&#8243;<\/td> <td>3 3\/4&#8243;<\/td> <td>4&#8243;<\/td> <\/tr> <\/tbody> <\/table><\/div> <p>*C Dimensions are approximate<\/p> <div class=\"grid\"><div class=\"c-two-third \"> <h4>Electronic Vacuum Pilot Regulator Details<\/h4> <p>For precise electronic control, using an Equilibar <a href=\"https:\/\/www.equilibar.com\/product\/electronic-pressure-regulators\/qpv-electronic-pressure-regulator\">QPV<\/a> or <a href=\"https:\/\/www.equilibar.com\/product\/electronic-pressure-regulators\/epr-30hg-electronic-vacuum-control\/\">EPR 30Hg<\/a> electronic vacuum pilot regulator is an excellent option. They can be mounted near the central process control system for easy process integration or mounted directly to the EVR. Both are available with analog signals of 4-20 mA and 0-10 VDC.<\/p> <p>It is easy to upgrade from a manual to an electronic vacuum pilot regulator. Watch our video\u00a0at right for a demonstration of installing a QPV1 as a pilot regulator for an EVR.<\/p> <p>These electronic vacuum regulators may be combined with any Equilibar EVR product in processes where computer control is desired.<\/p> <\/div><\/p> <div class=\"c-one-third \"> <p><iframe loading=\"lazy\" src=\"https:\/\/www.youtube.com\/embed\/EnS19RcRGck\" width=\"560\" height=\"200\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p> <\/div><\/div><div class=\"grid\"><div class=\"c-two-third \"> <h4>Remote Sense Vacuum Pilot Regulator Details<\/h4> <p>For optional remote sense control, the Equilibar <a href=\"https:\/\/www.equilibar.com\/application\/remote-sense-for-improved-vacuum-control\/\">Remote Sense Vacuum (RSV) regulator<\/a> is available. The RSV is a highly sensitive manual vacuum pilot regulator designed specifically to provide closed loop control of any Equilibar vacuum regulator (EVR). The RSV has a remote sense port that can be connected to a line near the controlled process or to the inlet of the EVR. The RSV works by using this remote sense input to carefully adjust the vacuum force applied to the pilot reference port of the EVR.<\/p> <p>During high flow conditions, the RSV increases the vacuum force applied to the pilot reference port to open the vacuum regulator more fully. The opposite occurs during low flow conditions. This active pilot adjustment coupled with the instantaneous response of the Equilibar EVR keeps the pressure stable from the lowest flow rates to the maximum capacity of the EVR. See plot at right.<\/p> <p>The RSV can be integrated with any Equilibar vacuum regulator to provide improved vacuum control at a <a href=\"https:\/\/www.equilibar.com\/application\/precision-vacuum-higher-capacity\/\">wider flow range<\/a>. A remote sense vacuum pilot is useful in processes where flow rates are varying widely. For installation information, see the <a href=\"https:\/\/www.equilibar.com\/PDF\/Equilibar-RSV_installation_and_maintenance_guide.pdf\">RSV installation manual.<\/a> <\/p> <\/div><\/p> <div class=\"c-one-third \"> <p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-17405 size-full\" src=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/RSV-control-plot.jpg\" alt=\"plot of RSV vacuum pilot control\" width=\"487\" height=\"402\" srcset=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/RSV-control-plot.jpg 487w, https:\/\/www.equilibar.com\/wp-content\/uploads\/2018\/11\/RSV-control-plot-300x248.jpg 300w\" sizes=\"auto, (max-width: 487px) 100vw, 487px\" \/><\/p> <\/div><\/div> ","protected":false},"excerpt":{"rendered":"<p>Customers can use the standard vacuum pilot regulator, SVP1 and SVP2, or request an upgrade to the RSV remote sense pilot regulator or the QPV1 or EPR-30 electronic pilot regulator. The table below outlined the options and types of pilot regulators.<\/p>\n","protected":false},"author":16,"featured_media":0,"parent":1429,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-sidebar-left.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16927","page","type-page","status-publish","hentry","btp_relation_tag-s-techarticle"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.3 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Control Pilot Vacuum Pressure of an Equilibar Vacuum Regulator<\/title>\n<meta name=\"description\" content=\"Equilibar vacuum regulators use a secondary pilot vacuum regulator, either manual or electronic, to control pilot vacuum pressure\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electronic Vacuum Regulator | Equilibar Precision Pressure Control\" \/>\n<meta property=\"og:description\" content=\"Equilibar electronic vacuum regulators allow you to control your process pressure through a computerized command signal.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/\" \/>\n<meta property=\"og:site_name\" content=\"Equilibar\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Equilibar\/114261858601579\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-19T18:21:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Electronic Vacuum Regulator from Equilibar\" \/>\n<meta name=\"twitter:description\" content=\"Equilibar electronic vacuum regulators allow you to control your process pressure through a computerized command signal.\" \/>\n<meta name=\"twitter:site\" content=\"@equilibar\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Control Pilot Vacuum Pressure of an Equilibar Vacuum Regulator","description":"Equilibar vacuum regulators use a secondary pilot vacuum regulator, either manual or electronic, to control pilot vacuum pressure","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/","og_locale":"es_ES","og_type":"article","og_title":"Electronic Vacuum Regulator | Equilibar Precision Pressure Control","og_description":"Equilibar electronic vacuum regulators allow you to control your process pressure through a computerized command signal.","og_url":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/","og_site_name":"Equilibar","article_publisher":"https:\/\/www.facebook.com\/pages\/Equilibar\/114261858601579","article_modified_time":"2023-12-19T18:21:49+00:00","og_image":[{"url":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"Electronic Vacuum Regulator from Equilibar","twitter_description":"Equilibar electronic vacuum regulators allow you to control your process pressure through a computerized command signal.","twitter_site":"@equilibar","twitter_misc":{"Tiempo de lectura":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/","url":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/","name":"How to Control Pilot Vacuum Pressure of an Equilibar Vacuum Regulator","isPartOf":{"@id":"https:\/\/www.equilibar.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/#primaryimage"},"image":{"@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/#primaryimage"},"thumbnailUrl":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif","datePublished":"2018-12-04T15:20:11+00:00","dateModified":"2023-12-19T18:21:49+00:00","description":"Equilibar vacuum regulators use a secondary pilot vacuum regulator, either manual or electronic, to control pilot vacuum pressure","breadcrumb":{"@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/#breadcrumb"},"inLanguage":"es-ES","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/"]}]},{"@type":"ImageObject","inLanguage":"es-ES","@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/#primaryimage","url":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif","contentUrl":"https:\/\/www.equilibar.com\/wp-content\/uploads\/2019\/04\/How-it-works-with-bleed-to-atm-300x189.gif"},{"@type":"BreadcrumbList","@id":"https:\/\/www.equilibar.com\/vacuum-regulators\/vacuum-pilot-regulators\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Vacuum Regulators and Vacuum Control Valves","item":"https:\/\/www.equilibar.com\/vacuum-regulators\/"},{"@type":"ListItem","position":2,"name":"How to Control Pilot Vacuum Pressure on Equilibar Vacuum Regulators"}]},{"@type":"WebSite","@id":"https:\/\/www.equilibar.com\/#website","url":"https:\/\/www.equilibar.com\/","name":"Equilibar","description":"Precision Fluid Control","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.equilibar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-ES"}]}},"_links":{"self":[{"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/pages\/16927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/comments?post=16927"}],"version-history":[{"count":0,"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/pages\/16927\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/pages\/1429"}],"wp:attachment":[{"href":"https:\/\/www.equilibar.com\/es\/wp-json\/wp\/v2\/media?parent=16927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}